Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08PL01649

Parcel: 133397390


Addresses:

130 S BONANZA AV


Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Permit Number - T08PL01649

Inspection Description - PLUMBING - FINAL

Inspection Status - Denied

Date Description Inspector Results Comments
11/17/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
11/17/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
11/14/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SECURE PIPING AT WH VALVE
2. INSTALL WATER HAMMER ARRESTORS
3. POLYBUTYLENE WATER TUBING TO REPLACE DW
SUPPORT & SECURE ALL PIPING IN ATTIC
PER UPC STANDARDS 42"
4. PROVIDE PROPER ALIGNMENT OF FITTINGS
5. OFFSET PIPING TO AVOID STRAIN ON FITTINGS
6. PROVIDE HB VAC BREAKERS
7. WATER FLEXES MAY NOT BE CONCEALED (AT TUB)
8. YOU MAY COVER WALLS ONLY