Permit: T08PL01613

Parcel: 136214650

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/14/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
11/13/2008 PLUMBING - FINAL Denied IVRS - Inspection :
There is no access to the site.| 920*
1. NO ACCESS INSIDE HOUSE
2. REMOVE ALL FOIL TAPE FROM WATER HEATER VENT
3. DO NOT COUPLE 2 PIECES OF DOUBLE WALL VENT PIPE WITH A PIECE OF SINGLE WALL
4. USE SIMPLE WALL PIPE FROM THE WATER HEATER DRAFT DIVERTOR UP INTO EXISTING DOUBLE WALL PIPE
5. PROVIDE 3 SCREWS IN EACH JOINT AND NO TAPE
6. RESCHEDULE WHEN SOMEONE WILL BE HERE
11/12/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
OK TO COVER YARD
COMPLETE WH VENTING
CORRECT T&P
INSTALL SEDIMENT TRAP