Permit: T08PL01608

Parcel: 110052350

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/14/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
11/13/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
SECURE VENT CONNECTOR W/SCREWS AT EACH JOINT PROPERLY MAKE UP EACH JOINT

T&P DRAIN MAY NOT REDUCE CU, CUPV, GALV
11/10/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE AN EXTERIOR SHUT OFF VALVE AT HOUSE
PROTECT PIPING PASSING THRU MASONRY
INSTALL MIN. 17 GAUGE TRACER WIRE W/YELLOW COATING
TERMINATE T&P VALVE OUTSIDE
SECURE VENT CONNECTOR W/SCREWS AT EACH CONNECTION
SEDIMENT TRAP REQUIRED AT WH GAS SUPPLY