Permit: T08PL01547

Parcel: 128020410


Addresses:

6122 E 16TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/03/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
10/30/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
PETITION OF APPEAL #508-08 ON SITE

1. PROVIDE NIPPLE WITH NO THREADS ON DISCHARGE END AND VACUUM BREAKER ON HOSE BIB
2. DOUBLE WALL VENT PIPING NEEDS TO FIT TOGETHER PROPERLY (LIKE FOR LIKE MATERIAL) AND HAVE ABILITY TO KEEP RAIN OUT OF STRUCTURE.
10/28/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. WATER HEATER TEMPERATURE & PRESSURE RELIEF SHALL GRAVITY DRAIN TO DAYLIGHT OR PROVIDE CITY SIGNED PETITION OF APPEAL FOR ALTERNATE FORM OF T&P RELIEF INSTALLED CORRECTLY ON SITE
2. REMOVE TAPE FROM ALL JOINTS OF VENT PIPING
WATER HEATER/FURNACE AND PROVIDE APPROVED FASTENERS AT ALL JOINTS.
3. VENT FROM WATER HEATER/FURNACE SHALL TERMINATE WITH FULL SIZE DOUBLE WALL VENT PIPING 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE
4. PROVIDE BONDING OF BUILDING GAS PIPING