Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T08PL01532
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/23/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* GAS CARD AT METER SW GAS 889-1888 |
|
| 10/21/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. TEST SHALL HOLD MINIMUM 10 PSI FOR 15 MINUTES WITH NO LOSS OF PRESSURE ON ENTIRE GAS PIPING SYSTEM 2. REINSTALL GROUND WIRE TO GROUND WIRE 3. PROVIDE BONDING OF BUILDING GAS SYSTEM 4. PROVIDE FIRM BEDDING UNDER ENTIRE GAS PIPING IN YARD 5. PROVIDE APPROVED GAS SHUT OFF VALVES AT BOTH APPLIANCES 6. VENT FROM FURNACE/WATER HEATER TO BE EXTENDED UP WITH DOUBLE WALL VENT PIPING FULL SIZE TO 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE WITH APPROVED VENT CAP. |