Permit: T08PL01504

Parcel: 110060340


Addresses:

3118 N DALE AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/23/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
10/17/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE MINIMUM 1" CLEARANCE FROM WOOD COMBUSTIBLE AT FURNACE VENT THRU ROOF WITH 3' TERMINATION ABOVE TOP OF COOLER INTAKE.
2. VENT FROM WATER HEATER TO BE CORRECT TRANSITION PIPING MADE UP CORRECTLY WITH FASTENERS AT EACH JOINT CONNECTION
3. PROVIDE BONDING OF BUILDING GAS PIPING SYSTEM
10/15/2008 PLUMBING - FINAL Not ready for Inspection