Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T08PL01329
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/25/2008 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
09/23/2008 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1. GAS LINE REPAIR NOT MADE OK. TAPE ALREADY COMING OFF. WILL REQUIRE AN APPROVED TAPE PRIMER TO BE USED ON TAPED JOINTS. TAPED PIPE IS LIMITED TO FITTINGS AND PIPING MARRED BY WRENCHES. TAPING TO BE SPIRALLY WRAPPED HALF OVERLAP DOUBLE WRAP OF MINIMUM 10 MIL. TAPE TO PROVIDE MINIMUM 40 MIL. THICKNESS. PRIMER REQUIRED. SEE INSTALLATION STD. 2006 UPC. 2. ALSO, OUTDATED VALVES WERE REPLACED WITH APPROVED VALVES. FURNACES WILL REQUIRE A SEDIMENT TRAP AND PER MANUFACTURES SPEC's. FLEX CONNECTORS MAY NOT BE REUSED 3. CONTINUED "NOT READY" WILL RESULT IN REINSPECTION FEE |
|
09/19/2008 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* |