Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T08PL01287

Parcel: 133483000

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/09/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
10/24/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
NO VENT SHALL SERVE AS A DRAIN
PROVIDE SOLVENT WELD COUPLING TO RECONNECT THE VENT
BACK CORRECTLY. PLEASE SEE 2006 UPC AND CITY OF TUCSON LOCAL AMENDMENTS FOR CORRECT DRAINAGE RECEPTOR FOR SOFTENER DRAIN.

CONTRACTOR TO PAY REFEE FOR NON-COMPLIANCE WITH NOTES FROM 9/19/08 INSP.
09/19/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PIPING TO BE SUPPORTED CORRECTLY AT CORRECT INTERVALS
2. PROVIDE LADDER FOR INSPECTION OF DRAIN PIPING IN ATTIC SPACE
3. PIPING FOR DRAIN IS REQUIRED TO GO TO AN APPROVED DRAINAGE RECEPTOR