| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/09/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 10/24/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO VENT SHALL SERVE AS A DRAIN PROVIDE SOLVENT WELD COUPLING TO RECONNECT THE VENT BACK CORRECTLY. PLEASE SEE 2006 UPC AND CITY OF TUCSON LOCAL AMENDMENTS FOR CORRECT DRAINAGE RECEPTOR FOR SOFTENER DRAIN. CONTRACTOR TO PAY REFEE FOR NON-COMPLIANCE WITH NOTES FROM 9/19/08 INSP. |
|
| 09/19/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PIPING TO BE SUPPORTED CORRECTLY AT CORRECT INTERVALS 2. PROVIDE LADDER FOR INSPECTION OF DRAIN PIPING IN ATTIC SPACE 3. PIPING FOR DRAIN IS REQUIRED TO GO TO AN APPROVED DRAINAGE RECEPTOR |