Permit: T08PL01232

Parcel: 113090980


Addresses:

2620 N TYNDALL AV

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
10/06/2008 PLUMBING - INTERMEDIATE Approved
08/20/2008 PLUMBING - INTERMEDIATE Not ready for Inspection REQUIRE PETITION OF APPEAL FOR T&P RELIEF DRAIN
1. PLUG OFF DRAIN PAN OUTLET
2. NO THREADED END ON PRESSURE RELIEF VALVE
3. NO AVB ON HOSE BIB
4. NO BOND BETWEEN GAS AND WATER PIPING
5. VENT NOT APPROVED
6. WATER HEATER TO BE INSTALLED SO MAINTENANCE, REPAIR, REPLACEMENT CAN BE MAINTAINED
7. NO SEDIMENT TRAP

NOTE: GAS PIPING NOT ALLOWED ON FLOOR (3" ABOVE GRADE)