Permit: T08PL01133

Parcel: 107140200


Addresses:

525 E ALTURAS ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08PL01133

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/21/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
08/18/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE CITY APPROVED GAS ISOMETRIC IF FUTURE GAS IS NEEDED FOR ROOFTOP UNIT OR REMOVE TEES FOR FUTURE ROOFTOP UNIT AND OTHER FUTURE TEE ON ROOF
2. EXTEND GAS PIPE INTO WATER HEATER ENCLOSURE WITH RIDGID PIPE NIPPLE
3. INSTALL DRAFT HOOD PROPERLY AND VENT PIPING FOR WATER HEATER IN CORRECT DIRECTION OF FLOW
4. SEAL GAS PIPING INTO BUILDING
5. PROVIDE BONDING OF GAS SYSTEM
6. PLEASE FIND LISTING ON PIPE AND SHOW US ITS LISTING
7. PROVIDE PIPE PROTECTION PLATES AS REQUIRED

LUIS 977-8339
08/14/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
NO ACCESS AT 9:08 PROVIDE ACCESS AT NEXT INSPECTION
08/13/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*