Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/17/2008 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 08/13/2008 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. YOUR NEW WATER HEATER HAS A WARNING LABEL ON IT NOT FOR USE IN A MOBILE HOME. WATER HEATER REQUIRES DRIP PAN AND PERMIT FOR NEW INSTALL OF WATER HEATER TO BE ADDED TO THIS PERMIT AT 201 N STONE AV 2. VENT FROM WATER HEATER TO BE APPROVED VENT MATERIAL TERMINATING 3' ABOVE TOP OF COOLER WHEN WITHIN 10' OF COOLER INTAKE 3. YOU NEED AN APPROVED MOBILE HOME SHUT OFF VALVE AND FLEX AT METER LOCATION LIST NOT COMPLETE 4. YOUR WATER HEATER ENCLOSURE NEEDS TO BE SHEETROCKED WITH 1/2" DRYWALL FOR YOUR SAFETY AND CHECK THE FLOOR OF THE WATER HEATER ENCLOSURE FOR CORRECT SUPPORT OF WATER HEATER |
|
| 08/11/2008 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE NEW GAS FLEXES 2. PROVIDE APPROVED SUPPORT ON ALL GAS PIPING 3. PROVIDE NEW PSI TEST |