Permit: T08PL01086

Parcel: 140100060

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08PL01086

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/01/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
GAS CARD AT METER
07/29/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
SUPPORT PIPING FOR GAS AT 8' INTERVALS - AND CHANGES OF DIRECTION, THE FLEX AT THE FURNACE CANNOT PASS THRU THE METAL SEPARATION OF THE FURNACE COMPARTMENTS THIS MUST BE A RIDGID PIPE NIPPLE. FAILURE TO MAKE CORRECTIONS WILL RESULT IN REINSPECTION FEE
07/24/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SEE NOTE #2 ABOVE & COMPLY
2. REMOVE A PORTION OF THE SKIRT FOR UNDER MOBILE HOME PIPE INSPECTION TO COMPLY WITH NOTE #3 ABOVE
3. HAVE NEW WATER HEATER ADDED TO THIS PERMIT
4. PROVIDE A SEDIMENT TRAP AT GAS ENTRY TO WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN PIPE SHALL GRAVITY DRAIN TO DAYLIGHT AT EXPOSED LOCATION TERMINATING AT 90 DEG. DOWN 6" TO 24" FROM FINISH GRADE. PROVIDE A FULL SIZE PORT WATER SHUT OFF VALVE ON COLD WATER SUPPLY TO WATER HEATER.
07/22/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. THE TEST IS REQUIRED ALL THE WAY TO THE METER
2. HARD PIPE TO BELOW THE COMBUSTION CHAMBER AT THE FURNACE "A FLEX CONNECTOR MAY NOT PASS THROUGH A WALL OR PARTITION"
3. ALL UNDER FLOOR PIPING TO BE SECURE
4. REMOVE DOOR AT WATER HEATER FOR INSPECTION