Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T08PL01086
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/01/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* GAS CARD AT METER |
|
07/29/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SUPPORT PIPING FOR GAS AT 8' INTERVALS - AND CHANGES OF DIRECTION, THE FLEX AT THE FURNACE CANNOT PASS THRU THE METAL SEPARATION OF THE FURNACE COMPARTMENTS THIS MUST BE A RIDGID PIPE NIPPLE. FAILURE TO MAKE CORRECTIONS WILL RESULT IN REINSPECTION FEE |
|
07/24/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SEE NOTE #2 ABOVE & COMPLY 2. REMOVE A PORTION OF THE SKIRT FOR UNDER MOBILE HOME PIPE INSPECTION TO COMPLY WITH NOTE #3 ABOVE 3. HAVE NEW WATER HEATER ADDED TO THIS PERMIT 4. PROVIDE A SEDIMENT TRAP AT GAS ENTRY TO WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN PIPE SHALL GRAVITY DRAIN TO DAYLIGHT AT EXPOSED LOCATION TERMINATING AT 90 DEG. DOWN 6" TO 24" FROM FINISH GRADE. PROVIDE A FULL SIZE PORT WATER SHUT OFF VALVE ON COLD WATER SUPPLY TO WATER HEATER. |
|
07/22/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. THE TEST IS REQUIRED ALL THE WAY TO THE METER 2. HARD PIPE TO BELOW THE COMBUSTION CHAMBER AT THE FURNACE "A FLEX CONNECTOR MAY NOT PASS THROUGH A WALL OR PARTITION" 3. ALL UNDER FLOOR PIPING TO BE SECURE 4. REMOVE DOOR AT WATER HEATER FOR INSPECTION |