Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T08PL01029

Parcel: 121071100


Addresses:

5955 E LEE ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/09/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
07/08/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
FRONT HOUSE ONLY
1. PROVIDE A 10 PSI AIR TEST USING A GAUGE WITH 1/10TH PSI INCREMENTATIONS (15PSI)
2. REMOVE THREAD PROTECTOR AND INSTALL A LISTED PIPE COUPLING
3. SECURE PIPING DROP AT WH
NOTE WH INSTALLED W/OUT PERMIT
4. INSTALL SEDIMENT TRAP AT WH
5. CORRECT VENT
6. SECURE TO WH DRAFT COLLAR
7. PROPERLY TERMINATE T&P DRAIN