Permit: T08PL01025

Parcel: 13015197A


Addresses:

4557 E 29TH ST

Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/28/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
GAS CARD AT METER

PROVIDE BONDING PER NOTE #4 7/8/08 INSP.
07/08/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE TEST GAUGE IN 1/10TH POUND INCREMENTS AND TEST PRESSURE OF MINIMUM 10PSI ON GAS ENTIRE GAS SYSTEM AT TIME OF INSPECTION
2. PROVIDE AGA OR CSA APPROVED GAS VALVES AT ALL APPLIANCES WITH TEST UP TO THESE VALVES AT TIME
OF INSPECTION
3. PROVIDE BONDING OF BUILDING GAS SYSTEM
4. VENT FROM WATER HEATER/FURNACE TO HAVE
3-APPROVED FASTENERS AT EACH JOINT BE DOUBLE
WALL VENT PIPING (FULL SIZED) THRU CEILING AND ROOF TERMINATING 3' ABOVE TOP OF COOLER INTAKE WITH APPROVED DOUBLE WALL VENT CAP