Inspection History: SITE - SEWER

Permit Number - T08PL01004

Inspection Description - SITE - SEWER

Inspection Status - Approved

Date Description Inspector Results Comments
10/27/2009 SITE - SEWER Approved
06/17/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
06/15/2009 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
INTERCEPTOR TO BE INSPECTED BY LEERAY HANLY
06/12/2009 SITE - SEWER Partial Approval INSPECTED VENT (35' +/-) 2" PVC UNDERGROUND, DUCTILE ABOVE; OIL/WATER SEPARATOR & 4" HCS TO SEPARATOR NORTH OF TIRE WASH (BLD 7). TEST OK, OK TO COVER.
11/18/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
ALL TESTING ON SEWER DONE TODAY
11/17/2008 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
11/13/2008 SITE - SEWER Partial Approval
11/12/2008 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
CONTRACTOR TO PIECE TOGETHER ALL DATA PERTAINING TO ALL WORK PERFORMED ON PRIVATE SEWER AFTER 09/08/08
AND CONVINCE INSPECTOR OF COMPLIANCE
09/08/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
BASES SET FOR MH #12, 13, 14 AND 9
09/03/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
NO NEW WORK TODAY
CALL 03057 AND LEAVE MESSAGE FOR BASES AND MANHOLES
09/02/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
BACKFILLING BETWEEN MH #13 AND MH #9
08/29/2008 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
08/26/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
PRE-CON MEETING WITH F.W.W.D FOR SITE WATER DISTRIBUTION - NO NEW SEWER INSTALLED
08/25/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
8" SDR 35 FROM MH.#13 TO MH.#14 OK
TO COVER SUBJECT TO VERIFICATION
OF GRADE AND TEST AT A LATER DATE
08/22/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
JENSEN PRE-CAST SETTING MANHOLE's TODAY
08/21/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
FROM MH #13 EAST TO CLEANOUT
WEST PLUS OR MINUS 50'
OK TO COVER SUBJECT TO VERIFICATION OF GRADE
AND TEST AT A LATER DATE
08/20/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
1. BASES SET #3, #4, #5, #11
2. PIPE LAYED BETWEEN #11 & #12 W/TRACER
3. DIGGING FOR OIL/WATER SEPARATOR JUST BEFORE TIE IN AT EXISTING MANHOLE
4. PLUS OR MINUS 80' PAST M.H #12
08/20/2008 SITE - SEWER Partial Approval FROM MH #13 WEST TO BLDG. SERVICE AT 4000 N SUN TRAN
FROM MH #13 EAST 100' OF TRENCH
08/15/2008 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
08/13/2008 SITE - SEWER Partial Approval CONTRACTOR STARTING TO DIG
08/12/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
1. PIPING EXTENDED TO M.H #4 WITH ONE BRANCH
OK TO COVER
2. 8" SDR 35 FROM MH#4 TO MH#5 INSTALLED OK WITH ONE LATERAL BRANCH.
3. CONTRACTOR TO INSURE TRACER BEING INSTALLED
4. D.I.P INSTALLED OK
5. OK TO COVER SUBJECT TO VERIFICATION OF GRADE AND A TEST AT A LATER DATE
07/30/2008 SITE - SEWER Partial Approval NO NEW WORK PERFORMED
07/25/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
- D.I.P INSTALLED TO MH #3 -- NEEDS TO BE WRAPPED
- 6" SDR 35 X 30 FEET INSTALLED BRANCH
- 8" SDR 35 FROM MANHOLE #3 TO MANHOLE #4 PLUS OR MINUS 200'
- OK TO COVER SUBJECT TO VERIFICATION OF GRADE AND TEST AT A LATER DATE
07/24/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
FROM EXISTING MANHOLE NORTH TO TWENTY FEET SHORT OF MANHOLE NUMBER THREE. 8" SDR 35 WITH TRACER INSTALLED OK. SUBJECT TO VERIFICATION OF GRADE AND TEST AT A LATER DATE. OK TO COVER.