Permit: T08PL00994

Parcel: 127101030


Addresses:

6180 E 2ND ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08PL00994

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/21/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
PETITION OF APPEAL #147-08 ON SITE
08/07/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE CORRECT COMBUSTION AIR FOR BTU REQUIREMENTS OF WATER HEATER
2) CUT T & P DRAIN PIPE MINIMUM 1" ABOVE TOP LIP OF DRAIN PAN
3) HAVE PETITION OF APPEAL FOR ALTERNATE FORM OF TEMPERTURE AND PRESSURE RELIEF SIGNED BY CITY OF TUCSON ON SITE
4) PROVIDE NIPPLE WITH NO THREADS ON DISCHARGE END OF OUTLET OF 125 POUND PRESSURE RELIEF DEVICE AT HOSE BIB ON EXTERIOR