Permit: T08PL00987

Parcel: 131071270


Addresses:

6142 E 26TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/11/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
07/08/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
WATER HEATER TEMPERATURE & PRESSURE RELIEF SHALL GRAVITY DRAIN TO DAYLIGHT TERMINATING AT 90 DEG. DOWN WITH APPROVED MATERIAL (COPPER, CPVC, GALV PIPE)
6" TO 24" FROM FINISH GRADE
06/30/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE 3-SCREWS AT ALL JOINTS OF WATER HEATER VENT PIPING
2. SECURE GAS PIPING AROUND DOORWAY
3. PROVIDE BONDING OF BUILDING GAS PIPING
4. TERMINATE WATER HEATER T&P AT 90 DEG. DOWN