Permit: T08PL00980

Parcel: 140411000


Addresses:

6850 S BROSIUS AV


Inspection Status: Approved

Inspection History: SITE - SEWER

Permit Number - T08PL00980

Inspection Description - SITE - SEWER

Inspection Status - Approved

Date Description Inspector Results Comments
05/20/2009 SITE - SEWER Approved IVRS - Inspection :*
04/24/2009 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
SOUTH END TIE IN OK (ONLY)
04/23/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) TIE IN ON SOUTH END OF BLDG ONLY-OK
04/14/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) FROM RICK ENGINEER AT MEETING OK TO TIE IN
2) 1 SOUTH ? HCS'S, NOT NEW RESTROOM
04/01/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
03/31/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
03/30/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
BACKFILLING MANHOLES
03/27/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
TIE IN FOR NORTH SIDE RESTROOM AT SITE SEWER
03/26/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
PIPING FROM PRIVATE MANHOLE #1 TO PUBLIC MANHOLE #4
03/25/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
WORKING ON BACKFILLING AROUND MANHOLES
03/24/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
PROVIDE TEST ON ALL PIPING
AND MANHOLES, COMPLETE INSTALL OF ALL PIPES
03/23/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
MANHOLE #1 SACKED ALL MANHOLES TO BE VACUUM TESTED AT LATER DATE
03/20/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
8" DIP FROM PAD ADAPTOR UPSTREAM TO MANHOLE #2
BEDDING, BAGGING, LAYING, TRACER, SHADING OK

6" PVC SDR35 FROM MANHOLE #2 TO BLD. DRAIN AT 2-WAY C/O BEDDING, LAYING, TRACER TO BE INSTALLED OK

8" PVC SDR35 FROM MANHOLE #1 TOWARD PUBLIC MANHOLE (1) STICK, BEDDING, LAYING OK

MANHOLE #1 & #2 BASES OR TO BUILD
03/19/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
8" SDR35 CONTINUES FROM MANHOLE #1 TOWARD #2 TO PAD ADAPTOR TRANSITION TO DUCTILE IRON SP-2000
BEDDING, LAYING, TRACER OK
03/18/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
8" SDR35 FROM MANHOLE #1 TO C.O. #L
BEDDING, LAYING, TRACER OK TO SHADE AND BACKFILL PENDING 3RD PARTY OK