Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/19/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* GAS PIPING DELETE TO FIREPLACE PER R-2 REVISION GAS GRILL INSTALLED CORRECTLY AT THIS TIME |
|
| 09/09/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. MAKE ALL CONNECTIONS - HOOK UP ALL PIPE 2. GAS PIPING MAY NOT BE RUN AT GRADE, BUT MUST BE INSTALLED AT LEAST 3 1/2" ABOVE GRADE 3. GAS PIPING IN MASONRY BENCH INSTALLED AND COVERED WITHOUT INSPECTION 4. CONTRACTOR TO PAY REINSPECTION FEE NOTE: "NOT READY" MEANS YOU HAVE NOT COMPLIED WITH ALL OF THE PREVIOUS CORRECTIONS. DUE TO INSPECTION LOAD, I AM UNABLE TO WAIT FOR YOU ANY LONGER |
|
| 08/26/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 08/22/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. YOU DO NOT HAVE PERMISSION TO ACTIVATE GAS TO BBQ/FIREPLACE!!! 2. YOU EXCEEDED THE PLAN BY ADDING THE FIREPLACE THE GAS LINE MAY BE UNDERSIZED BECAUSE IT IS NOT SHOWN ON THE PLAN. PLUS, YOU ADDED MORE PIPING SINCE MY LAST INSPECTION THOSE CORRECTIONS ARE INDICATED ON REPORT FROM 8/19/08 CONTINUED "NOT READY" WILL RESULT IN REINSPECTION FEE |
|
| 08/19/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PLEASE PROVIDE APPROVED PLAN 2. PERMIT INDICATES GAS LINE FOR BBQ - YOU HAVE ADDED A FIREPLACE ALL PIPE TO BE SUPPORTED ALL PIPE TO BE TESTED PIPE MAY NOT PASS THRU MASONRY WITHOUT PROTECTION |
|
| 07/02/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* OK TO BACKFILL TRENCH AFTER ALL CONNECTIONS ARE MADE AND ALL PIPING RUN CALL 03090 FOR FINAL INSPECTION |
|
| 06/23/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. UNABLE TO LOCATE PLAN OR PERMIT 2. GAS LINE REQUIRES TRACER WIRE |