Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T08PL00968
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/29/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
07/08/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE CORRECT VENTING FOR WATER HEATER IF DOUBLE WALL VENT MATERIAL IS USED IT SHALL REMAIN DOUBLE WALL TO POINT OF TERMINATION. YOU CANNOT RUN SINGLE WALL INTO DOUBLE WALL AND GO BACK TO SINGLE WALL VENT MATERIAL. 2. PROVIDE 1" AIR GAP FOR TEMPERATURE AND PRESSURE RELIEF DRAIN LINE AND DRAIN PAN |