Permit: T08PL00968

Parcel: 133394340

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08PL00968

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
07/29/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
07/08/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE CORRECT VENTING FOR WATER HEATER
IF DOUBLE WALL VENT MATERIAL IS USED IT SHALL REMAIN DOUBLE WALL TO POINT OF TERMINATION. YOU CANNOT RUN SINGLE WALL INTO DOUBLE WALL AND GO BACK TO SINGLE WALL VENT MATERIAL.
2. PROVIDE 1" AIR GAP FOR TEMPERATURE AND PRESSURE RELIEF DRAIN LINE AND DRAIN PAN