Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T08PL00944
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/16/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
06/13/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. VENT DN STREAM OF GT SHALL BE TAKEN OFF ABOVE FLOW LINE. 2. A SAN T IS A VERTICAL FITTING, USE A WYE 3. CORRECT SLOPE ON FC AIR INLET 4. INSTALL P TRAP ON DRAIN PIPING BEFORE FC 5. PIPE SANITIZE COMPARTMENT INDIRECTLY TO FS |