Permit: T08PL00944

Parcel: 13623007Y

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08PL00944

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/16/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
06/13/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. VENT DN STREAM OF GT SHALL BE TAKEN OFF
ABOVE FLOW LINE.
2. A SAN T IS A VERTICAL FITTING, USE A WYE
3. CORRECT SLOPE ON FC AIR INLET
4. INSTALL P TRAP ON DRAIN PIPING BEFORE FC
5. PIPE SANITIZE COMPARTMENT INDIRECTLY TO FS