Permit: T08PL00919

Parcel: 121011890


Addresses:

1925 N RIDGEWAY RD

Inspection Status: Denied

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
06/10/2008 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
MEAN DOG!
1. PRIME AND WRAP BELOW GRADE PIPING AT REPAIRS
2. REMOVE DISCONNECTED PIPING AND UNPERMITTED PIPING ACROSS ROOF
3. PROVIDE ELECTRICAL BONDING
4. PROVIDE CORRECT WH T&P DRAIN TERMINATION
5. CORRECT WH AND FURNACE VENTS; GALV SINGLE WALL CONNECTORS W/3 SHEETMETAL SCREWS AT EA. JOINT
6. B VENT THROUGH CEILING AND ROOF W/PROPER TERMINATIONS
7. AGA VALVE AT FURNACE