Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/21/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 150.08 WH OK NO TEST ON GAS SYSTEM |
|
| 08/20/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* APPROX. ETA GIVEN NO ANSWER @ 11:15 AM |
|
| 08/19/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE PETITION OF APPEAL FORM W/BUILDING OFFICIAL SIGNATURE FOR ALTERNATE T&P TERMINATION OR PIPE TO APPROVED DUAL INLET WASHER BOX 2. CAP OLD T&P DRAIN CONN. TO SEWER VENT 3. CORRECT SINGLE WALL VENT CONNECTOR AT ADJ ELL BELOW B VENT CONNECTION 4. A GAS RECONNECT PERMIT AND PRESSURE TEST IS REQUIRED FOR GAS CLEARANCE |
|
| 06/13/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SECURE VENT CONN AT WH INSTALL AGA/CSA GAS VALVE AND FLEX SEDIMENT TRAP REQUIRED CORRECT T&P TERMINATION CONNECT TO EXISTING DO NOT TRAP USE APPROVED PIPING |