Permit: T08PL00903

Parcel: 133120460


Addresses:

7802 E EDISON ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/21/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
150.08
WH OK
NO TEST ON GAS SYSTEM
08/20/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
APPROX. ETA GIVEN
NO ANSWER @ 11:15 AM
08/19/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE PETITION OF APPEAL FORM W/BUILDING OFFICIAL SIGNATURE FOR ALTERNATE T&P TERMINATION OR PIPE TO APPROVED DUAL INLET WASHER BOX
2. CAP OLD T&P DRAIN CONN. TO SEWER VENT
3. CORRECT SINGLE WALL VENT CONNECTOR AT ADJ ELL BELOW B VENT CONNECTION
4. A GAS RECONNECT PERMIT AND PRESSURE TEST IS REQUIRED FOR GAS CLEARANCE
06/13/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
SECURE VENT CONN AT WH
INSTALL AGA/CSA GAS VALVE AND FLEX
SEDIMENT TRAP REQUIRED
CORRECT T&P TERMINATION
CONNECT TO EXISTING
DO NOT TRAP
USE APPROVED PIPING