Permit: T08PL00851

Parcel: 141350860

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Permit Number - T08PL00851

Inspection Description - PLUMBING - FINAL

Inspection Status - Denied

Date Description Inspector Results Comments
07/30/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
VINYL TUBING IS NOT APPROVED TO RUN THIS LONG OF A DISTANCE, DRAINAGE PIPING SHALL GRAVITY DRAIN, BE PROPERLY SUPPORTED AND HAVE 1" AIR GAP AT TERMINATION POINT, NOT BE BURIED IN THE GROUND
PLEASE TRANSITION TO APPROVED MATERIAL AT TANK.
06/11/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
OVERFLOW DRAIN TO TERMINATE AT AN APPROVED DRAIN RECEPTOR OR AT BUILDING EXTERIOR IN AREA WHERE IT CAN BE ABSORBED WITH APPROVED MATERIAL AWAY FROM FOUNDATION