Permit: T08PL00832

Parcel: 136304170

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T08PL00832

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
05/23/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
05/22/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ALL ANGLE STOPS TO BE PROPERLY SECURED
2) SECURE TUB AND SHOWER VALVES PROPERLY
3) PROVIDE APPROVED MATERIAL FOR SUPPLIES TO FIXTURES
4) SECURE PIPING AT WATER HEATER AREA PROPERLY
5) PROVIDE MINIMUM 6" METALIC PIPING AT WATER HEATER SUPPLY IN AND OUT OF WATER HEATER
6) PROVIDE FULL SIZE 1" DISTRIBUTION FOR CORRECT SIZING ON COLD INLET PIPING
7) SECURE AND SUPPORT PIPING IN ATTIC PROPERLY
8) PROVIDE VACUUM BREAKERS AT ALL HOSE BIBS