Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T08PL00778
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/05/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) RECEIVED AUTHORIZATION TO DISCHARGE FROM PCDEQ |
|
08/04/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
02/26/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* MANHOLE #3 VACUUM TEST OK MANHOLE #2 VACUUM TEST OK MANHOLE #1 VACUUM TEST FAILED (RESCHEDULE WITH INSP. MYERS) WATER TEST EAST SIDE OF BLDG. FROM END OF LINE CLEANOUT, (3) 6" RAIN LEADERS (1) 4" RAIN LEADER FROM INTERIOR TIE INTO 8" EXTERIOR STORM DRAINAGE 8" SDR35 TO 8' PAST SOUTHEAST CORNER OF BLD. AIR TEST 8" SEWER FROM MANHOLE #1 TO #2 OK AIR TEST 8" SEWER FROM MANHOLE #2 TO #3 OK AIR TEST 8" SEWER FROM MANHOLE #1 TO PUBLIC MANHOLE OK |