Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08PL00778

Parcel: 11615088L


Addresses:

395 N SILVERBELL RD


Inspection Status: Approved

Inspection History: SITE - SEWER

Permit Number - T08PL00778

Inspection Description - SITE - SEWER

Inspection Status - Approved

Date Description Inspector Results Comments
08/05/2009 SITE - SEWER Approved IVRS - Inspection :*
03/02/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
02/26/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
01/27/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
OK TO POUR CONCRETE; SUBJECT TO VERIFICATION OF GRADE AND TEST AT A LATER DATE
01/23/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
PRE-SLAB FOR CONCRETE CAP FROM MANHOLE #1 TO #2
01/22/2009 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
TOO WET TO POUR
RESCHEDULE AND LEAVE MESSAGE
01/12/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
BASE NUMBER 3 SET TODAY
12/11/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
D.I.P BETWEEN MANHOLE #2 & #3 OK
SUBJECT TO TEST & VERIFICATION OF GRADE @ A LATER DATE
CALL 03057 FOR BASE NUMBER 3
11/18/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
2 BASES SET TODAY
11/14/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
1. WRAPPED DUCTILE IRON PIPE INSTALLED BETWEEN PUBLIC MANHOLE NUMBER TWO AND PRIVATE MANHOLE NUMBER ONE
D.I.P INSTALLED BETWEEN PRIVATE MANHOLE #1 AND PRIVATE MANHOLE #2 AND STUBBED OUT OF #2
OK TO COVER SUBJECT TO VERIFICATION OF GRADE AND TESTING AT A LATER DATE.
2. CALL 03057 WHEN BASES ARE SET