Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/24/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 07/22/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* SEE NOTE #2 FROM 6/4/08 AND PROVIDE MINIMUM COMBUSTION AIR OPENING REQUIRED FOR BTU DEMAND OF 40,000 BTU WATER HEATER |
|
| 07/18/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 07/07/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* VENT FITTINGS INSTALLED IN WRONG DIRECTION OF FLOW |
|
| 06/04/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. VENT PIPING TO HAVE ALL TAPE REMOVED, PROVIDE APPROVED FASTENERS AT ALL JOINTS, DOUBLE WALL WITH 1" MINIMUM CLEARANCE THRU ROOF FROM COMBUSTIBLES TERMINATING WITH APPROVED DOUBLE WALL VENT CAP. 2. PROVIDE MINIMUM UPPER COMBUSTION AIR OPENING FOR BTU REQUIREMENTS OF WATER HEATER. |