Permit: T08PL00715

Parcel: 108200380


Addresses:

4019 N FREMONT AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/06/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
10.5 PSI
464-08 P OF A

SECURE PIPE AT WH AND WRAP ALL TOOL MARKS BELOW GRADE AS PREVIOUSLY INSTRUCTED.
05/05/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- TYPE B VENT REQUIRED ABOVE ROOF SECURE GAS PIPE DROP AT WH "CLAMP TO WALL NOT TO WH AND PROVIDE CLEARANCE FOR REMOVAL OF WH"
- T&P MAY NOT GO UP
PROVIDE A PETITION OF APPEAL FOR T&P AND INSTALL A PAN AND EXTERIOR RELIEF VALVE

NOTE: HOMEOWNER IS HOSTILE AND BLAMES INSPECTOR FOR PROBLEMS EVEN THOUGH HIS WH WAS INSTALLED W/OUT PERMITS AND HAS HIRED A PERSON THAT IS NOT KNOWLEDGEABLE OF THE CODE REQUIREMENTS FOR A GAS INSTALLATION.
05/02/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- 12" REQUIRED COVER BELOW GRADE
- ROOF FLASHINGS REQUIRED AT ROOF PENETRATIONS
- PROPER ALIGNMENT OF PIPING
- SUPPORT AT EACH END AND NOT MORE THAN 8'
- SECURE DROPS
- EXTEND WH B-VENTS ABOVE COOLER
- SECURE VENT CONNECTORS W/3 SCREWS AT EACH JOINT
- HARD PIPE T&P AND VERIFY EXTERIOR TERMINATION
- UPPER COMBUSTION AIR OPENING AT WH