Permit: T08PL00710

Parcel: 133281260


Addresses:

8438 E 5TH ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08PL00710

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/06/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
05/05/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1 1/2 PIPE STUFFED DOWN INSIDE 2" PIPE IS A CODE VIOLATION. PROVIDE THE CORRECT REDUCING FITTING AND TRANSITION FITTING. USE A 2 X 1 1/2 X 1 1/2 SAN T

INSTALL MISSING 3" SEWER CLEAN OUT ADAPTOR FITTING AND PLUG. SEAL THREADS. AN OPEN PIPE IS AN UNSANITARY CONDITION.

PLUMB. VERTICAL RISERS PROPERLY INSTALL CLAMPS ON VERTICAL RISERS
05/02/2008 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
RECONNECT EXISTING VENT TO PROTECT
TRAP SEAL ON KIT. SINK
05/01/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
ABS PIPING MAY NOT BE EXPOSED TO SUNLIGHT
SEE UPC IS #5 FOR ABS INSTALLATION STANDARDS
ABS SEWER BELOW GRADE SHALL HAVE 1' OF COVER
PROPER USE OF DRAINAGE FITTINGS REQUIRED
PROPER PIPE SUPPORTS REQUIRED
TEST ON ALL NEW PIPING
FULL PORT VALVE REQUIRED AFTER CHECK VALVE
USE PROPER TRANSITION BANDS
USE PERM CAP OR PLUG ON OLD DRAIN PIPE