Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T08PL00710
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/06/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 05/05/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1 1/2 PIPE STUFFED DOWN INSIDE 2" PIPE IS A CODE VIOLATION. PROVIDE THE CORRECT REDUCING FITTING AND TRANSITION FITTING. USE A 2 X 1 1/2 X 1 1/2 SAN T INSTALL MISSING 3" SEWER CLEAN OUT ADAPTOR FITTING AND PLUG. SEAL THREADS. AN OPEN PIPE IS AN UNSANITARY CONDITION. PLUMB. VERTICAL RISERS PROPERLY INSTALL CLAMPS ON VERTICAL RISERS |
|
| 05/02/2008 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* RECONNECT EXISTING VENT TO PROTECT TRAP SEAL ON KIT. SINK |
|
| 05/01/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* ABS PIPING MAY NOT BE EXPOSED TO SUNLIGHT SEE UPC IS #5 FOR ABS INSTALLATION STANDARDS ABS SEWER BELOW GRADE SHALL HAVE 1' OF COVER PROPER USE OF DRAINAGE FITTINGS REQUIRED PROPER PIPE SUPPORTS REQUIRED TEST ON ALL NEW PIPING FULL PORT VALVE REQUIRED AFTER CHECK VALVE USE PROPER TRANSITION BANDS USE PERM CAP OR PLUG ON OLD DRAIN PIPE |