Permit: T08PL00703

Parcel: 131052130


Addresses:

5402 E 30TH ST 0A

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/01/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
04/30/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE PIPING CONFIGURATION SO WATER HEATER CAN BE REMOVED
2. SUPPORT PIPING IN FURNACE/WATER HEATER CLOSET
3. PROVIDE COMBUSTION AIR FOR COMBINED BTU REQUIREMENTS FOR WATER HEATER/FURNACE
4. REMOVE ALL TAPE FROM VENT PIPING & PROVIDE APPROVED FASTENERS FOR ALL JOINTS OF VENT PIPING ON FURNACE AND WATER HEATER
5. PROVIDE BONDING OF BUILDING GAS SYSTEM
(NOT GROUNDING)
04/29/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE TEST OF MINIMUM 10 PSI AT TIME OF INSPECTION
2. NO ACCESS AT 8:40 -- LIST NOT COMPLETE