Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T08PL00672
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/29/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* GAS CARD AT METER SW GAS 889-1888 |
|
04/24/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PIPING TO BE CONFIGURED TO PROVIDE ABILITY TO REMOVE WATER HEATER 2. REMOVE ALL TAPE FROM VENT PIPING VERIFY CORRECT FASTENERS AT ALL VENT JOINTS. 3. WATER HEATER TEMPERATURE AND PRESSURE RELIEF DRAIN MUST GRAVITY DRAIN (CANNOT GO UPHILL) AND BE RIDGID PIPED 4. VENTS FROM WATER HEATER AND FURNACE TO BE EXTENDED UP WITH DOUBLE WALL VENT PIPING TO 3' ABOVE TOP OF COOLER WHEN WITHIN 10' OF COOLER INTAKE |