Permit: T08PL00613

Parcel: 114512280

Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - FINAL

Permit Number - T08PL00613

Inspection Description - PLUMBING - FINAL

Inspection Status - Not ready for Inspection

Date Description Inspector Results Comments
04/16/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE TEST ON COMPLETED NATURAL GAS SYSTEM WITH APPROVED GAS SHUT OFF VALVES AT APPLIANCES
2. PROVIDE SEDIMENT TRAP AT WATER HEATER
3. PROVIDE WEATHERPROOF ENCLOSURE FOR WATER HEATER WITH APPROVED VENT PIPING, PROPERLY SECURED WITH FASTENERS AT ALL JOINTS, DOUBLE WALL REQUIRED AT EXIT OF ENCLOSURE WITH 1" CLEARANCE FROM COMBUSTIBLES WITH APPROVED VENT CAP (NO TAPE ON JOINTS)
4. PROVIDE BONDING OF BUILDING GAS PIPING