Date Description Inspector Results Comments
12/19/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
12/16/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
NO ONE AT HOME UNABLE TO DO INSPECTION
08/29/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE DOUBLE WALL FLUE VENT
THRU ROOF WITH FLUE CAP
2. UNDERGROUND PIPING @ TEST OK
3. PROVIDE AGA VALVE AND FLEX AT STOVE
07/03/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE APPROVED FLUE VENT FOR WATER HEATER AND FURNACE
2. PROVIDE PSI TEST MIN. 10 PSI
3. COMPLETE LISTS ABOVE
05/27/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE 12" MIN. COVER FOR UNDERGROUND PIPING
2. ADD SUPPORT ON INSIDE WATER HEATER ROOM
3. COMPLETE LIST FROM 5/5/08
05/05/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE TAPE & PRIMER ON ALL FITTING AND TOOL MARKS FOR UNDERGROUND PIPING
2. COMPLETE INSTALL OF WATER HEATER AND FURNACE
3. PROVIDE PSI TEST ON ALL GAS PIPING
4. PROVIDE APPROVED SIZE PIPING FOR BTU INSIDE HOUSE
5. LIST MAY NOT BE COMPLETE
6. PROVIDE AGA APPROVED VALVES AND FLEXES