| 04/18/2008 | PLUMBING - FINAL | Approved | PLEASE ARRANGE FOR ACCESS TO METS PRESSURE TEST OK OK FOR GAS SW GAS 889-1888 |
|
| 04/14/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. WILL REQUIRE TEN POUND TEST ON ENTIRE SYSTEM AND ACCESS TO METER 2. WILL REQUIRE TAPE AND TAPE PRIMER ON UNDERGROUND SECTION TO 6" ABOVE GRADE. HALF OVERLAP DOUBLE WRAPPED IS REQ'D T&P RELIEF DRAIN TO BE HARD PIPED GRAVITY DRAIN ALL VALVES TO BE AGA OR CSA APPROVED REQUIRE SEDIMENT TRAPS AT WATER HEATER AND FURNACE |