Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/25/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* PROVIDE PERMIT FOR STRUCTURE, PROVIDE FLASHING FOR WATER HEATER VENT THRU ROOF |
|
| 04/23/2008 | PLUMBING - FINAL | Denied | 1. PROVIDE AN APPROVED GAS SHUT OFF VALVE AT FURNACE WITH A RIDGID NIPPLE THRU THE APPLIANCE HOUSING 2. VENT FROM FURNACE TO BE MADE UP CORRECTLY WITH APPROVED FASTENERS AT ALL JOINTS (NO TAPE) 3. PROVIDE RIDGID PIPE THRU WALL TO STOVE WITH APPROVED AGA OR CSA GAS SHUT OFF VALVE 4. REMOVE UNION AT IN WALL LOCATION BY WATER HEATER AND SUPPORT GAS PIPING AT THIS LOCATION AND BACK TO NEW METER LOCATION 5. WATER HEATER NEEDS TO BE INSTALLED CORRECTLY WITH 1" MINIMUM CLEARANCE FROM DOUBLE WALL VENT AND ROOF STRUCTURE (FLAMMABLE MATERIAL) WITH ROOF FLASHING AND VENT CAP |