Permit: T08PL00568

Parcel: 10603014A


Addresses:

104 E PRINCE RD

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
09/19/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
RECEIVED LETTER FOR OK FOR PEX OK
TYPE "M" COPPER
CORRECTIONS OK

CALL IN 03075 FOR CLOSET FLANGE INSPECTION PRIOR TO SETTING STOOLS
09/11/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. HORIZONTAL CLEANOUT EXTENSION TO BE A WYE
BRANCH 90 DEG. TO BE A SWEEP
2. PLAN CALLS FOR TYPE "L" COPPER
3. CLEANOUTS SHALL BE INSTALLED ABOVE THE FLOW LINE OF THE PIPE
09/10/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. TRAP ARM MAY NOT CHANGE SIZE
2. TRAP AND TRAP ARM TO BE SAME SIZE
3. TRAP ARM MAY BE ONLY ONE PIPE SIZE LARGER THAN THE TAILPIECE TO WHICH IS CONNECTED
4. POINT OF VENT MAY NOT BE BELOW TRAP WEIR
5. PROTECT ABS FROM METAL STUDS
6. CORRECT BACKPITCHED SECTIONS
7. TRAP ARM MAY ONLY CHANGE DIRECTION 90 DEG. WITHOUT ANOTHER CLEANOUT
09/05/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. PROVIDE CORRECT LONG RADIUS DRAINAGE FITTINGS
PER HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION
2. PROVIDE TESTING ON ALL PIPING
3. PROVIDE MID-SPAN SUPPORTS AND SUPPORT ALL PIPING AT CORRECT INTERVALS IN WALL AND OVERHEAD
4. PROVIDE CORRECT TRANSITION COUPLINGS
5. PROVIDE MINIMUM FALL ON ALL DRAINAGE PIPING
6. PROVIDE CORRECT DRAINAGE FITTING FOR DRAINAGE IN RESTROOM K & L FOR STOOLS (SANITARY CROSS IS NOT)
7. PROVIDE APPROVED PERM. CAPS

LIST NOT COMPLETE
08/29/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
CANCELED