Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08PL00542

Parcel: 12607033D


Addresses:

306 N ALVERNON WY


Inspection Status: Approved

Inspection History: SITE - SEWER

Permit Number - T08PL00542

Inspection Description - SITE - SEWER

Inspection Status - Approved

Date Description Inspector Results Comments
11/14/2008 SITE - SEWER Approved IVRS - Inspection :*
07/18/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
SEWER TO B7 HCS W/TEST OK
06/16/2008 SITE - SEWER Partial Approval AIR TEST BETWEEN MANHOLES OK
06/11/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
CO #20 - #29
DIP PER PLAN W/TEST
06/10/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
VACUUM TEST W/KEITH 20 SEC. OK
06/03/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
MH BASE OK
06/02/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
PIPING BETWEEN MH#1 AND MH#2 OK
AIR TEST LATER
WATER STOPS IN PLACE
05/29/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
PIPING FROM INSIDE CURB TO NEW MANHOLE W/WATER STOP OK
05/21/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
FROM CO 6 TO CO 8 ALSO CO 17 W/WATER TEST OK
05/09/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
FROM CO 4-6 OK
05/06/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
CORRECTION AT S27 OK TESTED TO CO 16
05/05/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
FROM CO #4 THRU CO #12, 13, 15
CORRECT SLOPE @ PIPE SEC 27
05/02/2008 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
04/28/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
FROM CLEANOUT #2 THRU #3 TO CLEANOUT #4
6" SDR WATER TEST OK
04/24/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
WATER TEST FROM C.O #1 TO 10' PAST C.O #2 - OK
04/21/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
FROM MH#2 THROUGH CO #10 W/WATER TEST
04/11/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
RON W/HICKAM @ 954-9151
PIPING BETWEEN CO 19 AND 27
04/04/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
6" PVC FROM MH #2 TO CO #20 W/WATER TEST OK