Permit: T08PL00501

Parcel: 128071510


Addresses:

724 S DEL VALLE AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/03/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
PROVIDE FULL SIZE DRAIN FOR T&P & BONDING OF BLD. GAP PIPING
REINSPECTION OK
04/01/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PRIME THEN TAPE ALL FITTING UNDERGROUND TO 6" ABOVE GRADE
2. SUPPORT ALL PIPING AT CORRECT INTERVALS & SECURE IT
3. PROVIDE ROOF FLASHINGS AT BOTH PIPE PENETRATIONS THRU ROOF
4. PROVIDE AGA OR CSA APPROVED GAS VALVES AT ALL APPLIANCES
5. PROVIDE GRAVITY DRAIN TO DAYLIGHT OF APPROVED MATERIAL (COPPER OR CPVC) WITH 90 DEG. TERMINATION DOWN, 6"-24" FROM FINISH GRADE FOR WATER HEATER
T&P DRAIN
6. PROVIDE BONDING OF BUILDING GAS PIPING AND GROUND ELECTRICAL SYSTEM

RETEST ENTIRE SYSTEM

7. TEST INTO HEARTH OF FIREPLACE
03/28/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
CANCELED BY RUBEN