Permit: T08PL00453

Parcel: 129024280


Addresses:

425 S STRATFORD DR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/28/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
03/25/2008 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
- CORRECT UNCONNECTED WH VENT
- PLUMB B VENT AND SECURE TO WH VENT CONNECTOR
WITH 3 GALV SHEET METAL SCREWS
- PIPE T&P TO EXTERIOR
- REMOVE LOCK SCREWS ON VACUUM BREAKERS
03/14/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
- HAMMER ARRESTORS AT LAUNDRY AND DW
- COMPLETE WH VENT, PROVIDE CLEARANCE FROM WOOD
- PROVIDE 12" OF COVER
- PROVIDE SEPARATION OF HW/CW
- SECURE TUBING IN WALLS AND ABV CEILING
- HB VAC BREAKER
- SECURE TRACER WIRE
- SEAL WALL PENETRATIONS