Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/21/2008 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 03/19/2008 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* | |
| 03/17/2008 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* | |
| 03/11/2008 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1. MIN. PRESSURE TEST 10 PSI 2. PROVIDE PRIMER AND TAPE ON ALL FITTING AND TOOL MARKS ON ALL UNDERGROUND PIPING 3. PROVIDE SUPPORT ON GAS PIPING TO STOVE AND UP WALL AND TO FURNACE 4. PROVIDE HARD PIPE TO STOVE AND ONE FLEX WITH AGA APPROVED SHUT OFF VALVE 5. PROVIDE 18" OF COVER FOR UNDERGROUND OUTSIDE OF WALL |