Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/11/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 3 SCREWS IN EACH JOINT |
|
| 03/10/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* FURNACE VENT MUST CONNECT TO BOTTOM OF TEE AND WH INTO SIDE INSTALL B VENT IN CORRECT DIRECTION OF FLOW PROVIDE PRESSURE TEST |
|
| 03/07/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* TEST W/15 PSI GAUGE COMPLETE VENTING FOR WH AND FURNACE FURNACE REQUIRES 4" VENT SINGLE WALL REQUIRES 6" CLEARANCE NEW FURNACE REQUIRES A PERMIT SEDIMENT TRAPS REQUIRED AT NEW WH & FURNACE BOND W/#5 GROUNDING WIRE FLEX NOT ALLOWED ON T&P PVC NOT APPROVED FOR T&P DISCHARGE |