Permit: T08PL00341

Parcel: 136243070


Addresses:

6970 E BROOKS DR


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08PL00341

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/03/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
02/27/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
TEST FROM METER TO APPLIANCE SHUT OFF VALVES OK
UNLESS SYSTEM IS WORKED ON TO INSTALL ITEM #2 THIS PAGE THEN RETEST

1. PROVIDE RIDGID NIPPLE THRU FURNACE APPLIANCE HOUSING
2. PROVIDE SEDIMENT TRAPS AT GAS ENTRY TO WATER HEATER AND FURNACE
3. PROVIDE 3-GALV SCREWS AT ALL JOINTS OF ALL VENT PIPING FROM WATER HEATER & FURNACE
4. PROVIDE BONDING OF BUILDING GAS PIPING SYSTEM
5. PROVIDE APPROVED VENT EXTENSION ON ROOF FOR FURNACE TO 3' ABOVE TOP OF INTAKE WHEN WITHIN 10' OF INTAKE WITH APPROVED VENT CAP
6. REPLACE DAMAGED VENT PIPE ON ROOF FOR WATER HEATER AND EXTEND TO 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF INTAKE