Permit: T08PL00327

Parcel: 135081690


Addresses:

7149 E 29TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/03/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
02/25/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
REMOVE THE TAPE MAKING CONTACT WITH THE PLASTIC P.E PIPING BEFORE COVERING.

1. PROVIDE APPROVED VENT PIPING FOR WATER HEATER AND FURNACE. LARGER DEMAND DEVICE (FURNACE) HALL VENT AS LOWER CONNECTION TO WYE FITTING WITH WATER HEATER TIE IN ABOVE. PROVIDE 3-GALV SCREWS AT EACH JOINT OF VENT CONNECTIONS. TERMINATE MINIMUM 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE.
2. WATER HEATER TEMPERATURE & PRESSURE RELIEF SHALL GRAVITY DRAIN WITH APPROVED RIDGID PIPING (NO FLEXES)
3. PROVIDE BONDING OF BUILDING GAS PIPING