Inspection History Details
Inspection Status: Approved
Inspection History: SITE - SEWER
Permit Number - T08PL00287
Inspection Description - SITE - SEWER
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/23/2008 | SITE - SEWER | Approved | IVRS - Inspection :* | |
09/22/2008 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* | |
03/05/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* VACUUM TESTING OK NOTIFIED ENGINEER OF MINIMUM 20 SECOND TEST REGARDLESS OF DEPTH |
|
02/29/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* LOW PRESSURE AIR TESTING TODAY |
|
02/28/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* UNDERGROUND COMPLETE NEXT-TESTING |
|
02/27/2008 | SITE - SEWER | Partial Approval | BRANCH PIPING FROM BLDG #9 OK POURED MANHOLE BASES TODAY CALL 03057 WHEN RINGS ARE STACKED |
|
02/26/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* BRANCH PIPING TO MH#2 & MH#3 FROM BLDG. 13, 12, 11 AND 10 OK TO COVER SUBJECT TO VERIFICATION OF GRADE AND TEST AT A LATER DATE |
|
02/25/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. 8" SDR 35 FROM MH#2 TO MH#3 OK TO COVER SUBJECT TO VERIFICATION OF GRADE AND TESTING AT A LATER DATE 2. RECALL 03057 ON SEWER INSTALL, AND/OR BASES BEING SET |
|
02/22/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* CONTINUATION OF 8" SDR 35 NORTH TO 10' SOUTH OF NEW MANHOLE #2 FROM EXISTING MANHOLE, BEDDING, LAYING, TRACER, SHADING OK |
|
02/21/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 8" SDR FROM EXISTING MANHOLE #1 GOING NORTH 20' TOWARD NEW MANHOLE #2 BEDDING, LAYING, TRACER, SHADE ON SITE |
|
02/20/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 8" SDR FROM EXISTING MANHOLE #11 TO NEW MANHOLE #1 BEDDING, LAYING, TRACER, SHADING OK WILL AIR TEST PIPING & VACUUM TEST MANHOLE AT LATER DATE |