Permit: T08PL00276

Parcel: 11604047A

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/13/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
1. OK TO COVER WITH CLEAN FILL
2. PRESSURE TEST OK
OK FOR GAS

SW GAS 889-1888
02/12/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
(TRY AN ISOMETRIC)
1. PLAN IS NOT CORRECT TOTAL DEVELOPED LENGTH EXCEEDS 80'
2. PIPE IS TO BE A MINIMUM OF 12" DEEP
3. FITTINGS AND MARRED PIPE TO HAVE TAPE PRIMER AND TAPE. HALF OVERLAP DOUBLE WRAPPED
4. TEST ENTIRE SYSTEM - USE 30# GAUGE IN 1/10 POUND INCREMENTATION
5. ALL VALVES TO BE AGA OR CSA APPROVED
6. WATER HEATER REQUIRES PERMIT AND INSPECTION
WILL REQUIRE PETITION OF APPEAL FOR T&P RELIEF DRAIN
7. WATER HEATER AND FURNACE REQUIRE SEDIMENT TRAPS