Permit: T08PL00261

Parcel: 133397720


Addresses:

81 S GOLD MINE LP

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/15/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
02/13/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
FAILURE TO COMPLY AND OR CANCEL INSPECTION HAS RESULTED IN A REINSPECTION FEE. NO FINAL INSPECTION WILL BE GIVEN UNTIL FEE IS PAID
02/12/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. WATER HEATER VENT TO BE PROPERLY CONNECTED AT DRAFT HOOD AND HAVE 3-GALV SCREWS AT EACH VENT JOINT
2. PROVIDE 18" MINIMUM COPPER PIPING IN WALL AT WATER HEATER
3. SECURE WASHER HOSE VALVES & WASHER BOX
4. REPAIR LEAK AT MASTER BATH FAUCET AND SECURE PIPING
5. REPAIR LEAK AT MASTER LAV
6. PROVIDE SEPARATION OF HOT & COLD TUBING
7. PROPERLY SUPPORT & SECURE TUBING IN ATTIC.
NO TUBING SHALL COME IN CONTACT WITH ANY SHARP EDGES OF ANY KIND.
8. SECURE PIPING AT BUILDING ENTRY
SEAL PIPING ENTRY INTO BUILDING
FAILURE TO MAKE ALL CORRECTIONS WILL
RESULT IN REINSPECTION FEE AT REINSPECTION.