Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/15/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 02/13/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* FAILURE TO COMPLY AND OR CANCEL INSPECTION HAS RESULTED IN A REINSPECTION FEE. NO FINAL INSPECTION WILL BE GIVEN UNTIL FEE IS PAID |
|
| 02/12/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. WATER HEATER VENT TO BE PROPERLY CONNECTED AT DRAFT HOOD AND HAVE 3-GALV SCREWS AT EACH VENT JOINT 2. PROVIDE 18" MINIMUM COPPER PIPING IN WALL AT WATER HEATER 3. SECURE WASHER HOSE VALVES & WASHER BOX 4. REPAIR LEAK AT MASTER BATH FAUCET AND SECURE PIPING 5. REPAIR LEAK AT MASTER LAV 6. PROVIDE SEPARATION OF HOT & COLD TUBING 7. PROPERLY SUPPORT & SECURE TUBING IN ATTIC. NO TUBING SHALL COME IN CONTACT WITH ANY SHARP EDGES OF ANY KIND. 8. SECURE PIPING AT BUILDING ENTRY SEAL PIPING ENTRY INTO BUILDING FAILURE TO MAKE ALL CORRECTIONS WILL RESULT IN REINSPECTION FEE AT REINSPECTION. |