Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T08PL00225

Parcel: 99999999A

Inspection Status: Approved

Inspection History: SITE - SEWER

Date Description Inspector Results Comments
02/11/2009 SITE - SEWER Approved
08/19/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
1. MANHOLE TESTING ALL 3 MANHOLE VACUUM TESTING OK
2. RICK ENG. HAS PAPERWORK ON SITE FOR TESTING
08/12/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
1. TESTING FOR MANHOLE #2 TO #3,
RICK ENG. PROVIDING PAPERWORK
2. MANHOLE #2 TO #3 OK
3. MANHOLE #1 TO #2
4. AIR TESTING TO BE COMPLETE BY BOB FROM RICK ENG.
08/08/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
1. PER HIGHLIGHT ON PAGE 4 OF 4
2. TESTING TO BE DONE AT LATER DATE
08/04/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
8" SDR 35 FROM MANHOLE #2 TO MANHOLE #3
08/01/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
8" SDR CONTINUES FROM MANHOLE #2 TO APP. 40' FROM MANHOLE #3, BEDDING, LAYING, TRACER, SHADING, BACKFILL LINE -- EXCAVATION CONTINUES FOR 4" HCS FROM C/O B- LOCATION TOWARD BLD. 1
07/31/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
4" STUBBED OUT OF NEW MANHOLE #1 TO C/O A LOCATION
MANHOLE #1 BASE POURED

4" CONTINUOUS FROM MANHOLE #2 TO C/O B LOCATION
MANHOLE #2 BASE POURED

8" FROM MANHOLE #2 SOUTH APP. 100' BEDDING, LAYING, TRACER, SHADING
07/30/2008 SITE - SEWER Partial Approval IVRS - Inspection :*
8" SDR 35 FROM EXISTING STUB FROM EXISTING MANHOLE #452306 TO NEW MANHOLE #1 CONTINUES EAST TO
MANHOLE #2 WITH 4" EAST APP. 40' FROM MANHOLE #2 EAST, BEDDING, LAYING, TRACER, SHADING