Permit: T08PL00207

Parcel: 128120150


Addresses:

825 S JANET AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/05/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
SEE NOTE #3 FROM 2/1/08
COMPLETE INSTALL OF FURNACE WITH CORRECT VENTING
FOR BOTH WATER HEATER AND FURNACE. COMPLETE
ITEM #5 FROM 2/1/08
02/01/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. COMPLETE GAS PIPING IN ITS ENTIRETY WITH APPROVED GAS SHUT OFF VALVES AND TEST SYSTEM AT MINIMUM 10 PSI FOR 15 MINUTES WITH NO LOSS OF PRESSURE AT TIME OF INSPECTION.
2. SUPPORT GAS PIPING
3. PROVIDE CORRECT VENTING FOR FURNACE/WATER HEATER
4. PROVIDE TEMPERATURE & PRESSURE RELIEF DRAIN PIPING FOR WATER HEATER
5. PROVIDE BONDING OF BUILDING GAS SYSTEM