Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T08PL00159

Parcel: 113080780


Addresses:

1281 E GLENN ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
02/14/2008 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
02/08/2008 PLUMBING - GAS PRESSURE TEST Cancelled IVRS - RI canceled
02/05/2008 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
NOBODY HOME
CONTRACTOR TO PAY REINSPECTION FEE
01/30/2008 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1. I CALLED 440-4212 TWICE AND LEFT MESSAGES
2. NOBODY HOME
CONTINUED "NOT READY" WILL RESULT IN A
REINSPECTION FEE
01/28/2008 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*
PRESSURE TEST OK
1. CORRECT SLOPE ON VENT CONNECTOR
2. TYPE B REQUIRED ABOVE ROOF
3. PIPE T&P TO EXTERIOR W/MATERIALS ALLOWED FOR HOT WATER USE
4. SUPPORT GAS PIPING W/NEW WEATHER RESISTANT PIPE SUPPORTS. FIRST SUPPORT SHALL BE WITHIN 1' OF ROOF PENETRATION
5. SEDIMENT TRAP REQUIRED AT FURNACE REGULATOR
6. SEAL WALL PENETRATIONS